Instruction Manual
Model 2416-x02
Multi Channel Downconverter
2416-402 Four Channel • 2416-302 Three Channel • 2416-202 Two Channel • 2416-102 One Channel
April 2015, Rev. D
MENU
EXECUTE
MODEL 2416
CROSS TECHNOLOGIES INC.
DOWNCONVERTER
REMOTE
POWER
ALARMS
1674.125 1926.250
1926.375 2086.625
------ CH 1 -------- ------ CH 2 --------
1234
------ CH 3 -------- ------ CH 4 --------
A
B
(Shown, Model 2416-402 - Four Channel, Front Panel)
Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc.,
but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc.
for purposes of operating the equipment.
When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number,
equipment serial number, and a description of the part.
CROSS TECHNOLOGIES, INC.
6170 Shiloh Road
Alpharetta, Georgia 30005
(770) 886-8005
FAX (770) 886-7964
Toll Free 888-900-5588
WEB www.crosstechnologies.com
Vue de la page 0
1 2 3 4 5 6 ... 24 25

Résumé du contenu

Page 1 - Model 2416-x02

Instruction Manual Model 2416-x02Multi Channel Downconverter2416-402 Four Channel • 2416-302 Three Channel • 2416-202 Two Channel •

Page 2 - Alpharetta, Georgia 30005

(C) Commands Table 1.2 lists the commands for the 2416-x02 and briefly describes them. After a command is sent the 2416-x02 sends a return “>” ind

Page 3

1.5 Environmental Use InformationA. Rack-Mounting - To mount this equipment in a rack, please refer to the installation instructions located in the u

Page 4 - 1.2 Technical Specificaions

2.0 Installation2.1 MechanicalThe 2416-x02 consists of one RF/Controller PCB housed in a 1 RU (1 3/4 inch high) by 16 inch deep chassis. A switchin

Page 5

2.2 Rear Panel Input/Output Signals Figure 2.2 shows the input and output connectors on the rear panel. PSA & PSB - POWER INAC inpu

Page 6

2.3 Front Panel Controls and Indicators - The following are the front panel controls and indicators.MENUEXECUTE1674.125 1926.250REMOTE POWERLCD FR

Page 7

2.4 Operation2.4.1 Installing and Operating the 2416-x02 Downconverter1. Connect a -50 dBm to -20 dBm signal to RF IN, J2 (Figure 2.2).2. Connect t

Page 8 - B) Status Requests

2.5 Power On SettingsFigure 2.5 shows the various Front Panel LCD Displays that you will see during the Power Up sequence and the Settings modes. Th

Page 9 - Command Syntax* Description

2.5.2 Frequency ChangesAt any time during the modification process, if you have made a mistake and do not wish to save the changes you have made, do

Page 10 - {aaCOxxxxx} where x = :

2.6 Menu SettingsAll program changes must start with the operation of the Menu/Execute switch and must also end with the operation of the Menu/Execut

Page 11

3.0 Ethernet Interface Installation and Operation (Option W8, W18 or W28)This manual applies to Cross Technologies products equipped with a 10/100 Ba

Page 12

INSTRUCTION MANUALModel 2416-x02 Multi Channel DownconverterTABLE OF CONTENTS PAGEWarranty 21.0 General 31.1 Equipment Description 31.2 Technica

Page 13

Figure 3.1: Configuration Manager Screen(Example above shows Configuration Manger Screen for Model 2416-402) Once logged in, you will be presented

Page 14

Figure 3.2: Network Settings Web Page Screen(Example above shows Network Settings Screen for Model 2416-402)2416-402 Manual, Rev. D

Page 15 - SPARE FUSE

3.3 Web Page M & CEnter the following address in a web browser to access the M&C web page:http://<ip address>/serial/0/setup.htm where

Page 16

3.4 SNMP ConfigurationSetting of SNMP parameters such as Community Write and Community Read strings requires a Telnet® connection to port 9999. The f

Page 17

If you select Public, access is allowed for any number of authorized IP addresses of SNMP Managers. It is not required to enter IP Addresses of SNMP

Page 18

CROSS TECHNOLOGIES, INC.6170 Shiloh RoadAlpharetta, Georgia 30005(770) 886-8005FAX (770) 886-7964Toll Free 888-900-5588WEB www.crosstechnologies.com E

Page 19

Model 2416-x02 Multi Channel Downconverter2416-402 Four Channel • 2416-302 Three Channel • 2416-202 Two Channel • 2416-102 One Channel1.0 Gener

Page 20

1.2 Technical Specificaions <-60 dB typical, <-50 dB min.; G = 30, -30 dBm input level Channel to Channel isolation -50 to -20 dBm Input

Page 21

(Technical Specifications continued from page 4...) 140 ±36/70 ±18 MHz Selectable W140/70-x Ethernet with Web Browser W8 - Redundant Power Suppl

Page 22

1.3 Engineering Application (Note 1): Fractional PLL (Phase Lock Loop) ImplementationThe purpose of this Engineering Application Note is to inform ou

Page 23

1.4 Monitor and Control InterfaceA) Remote serial interfaceProtocol: RS-232C, 9600 baud rate, no parity, 8 data bits, 1 start bit, and 1 stop bit

Page 24

B) Status Requests Table 1.1 lists the status requests for the 2416-x02 and briefly describes them.* PPLEASE NOTE: Status requests of values specific

Page 25 - CROSS TECHNOLOGIES, INC

(Status Request continued from page 7...)TABLE 1.1 2416-x02 Statuus Status Requests Coontinued TABLE 1.1 2416-x02 Status Requests Contin